{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T11:13:36.110","vulnerabilities":[{"cve":{"id":"CVE-2024-34771","sourceIdentifier":"productcert@siemens.com","published":"2024-05-14T16:17:29.187","lastModified":"2025-03-07T16:00:12.453","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Solid Edge (All versions < V224.0 Update 2). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Solid Edge (Todas las versiones &lt; V224.0 Actualización 2). La aplicación afectada es vulnerable al desbordamiento de búfer de almacenamiento dinámico mientras analiza archivos PAR especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2024:*:*:*:*:*:*:*:*","versionEndExcluding":"224.0","matchCriteriaId":"D3887095-4E46-43B0-8A1E-4938EB474419"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2024:224.0:-:*:*:*:*:*:*","matchCriteriaId":"A0119E8F-1FAF-4A3B-B6E9-20F78360FC82"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge_se2024:224.0:update_0001:*:*:*:*:*:*","matchCriteriaId":"829C4AEB-7C8D-408B-A79C-8684753F45E1"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-589937.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-589937.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}