{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-17T06:08:32.079","vulnerabilities":[{"cve":{"id":"CVE-2024-34085","sourceIdentifier":"productcert@siemens.com","published":"2024-05-14T16:17:22.840","lastModified":"2025-10-03T19:54:59.777","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V2312.0001), Teamcenter Visualization V14.1 (All versions < V14.1.0.13), Teamcenter Visualization V14.2 (All versions < V14.2.0.10), Teamcenter Visualization V14.3 (All versions < V14.3.0.7), Teamcenter Visualization V2312 (All versions < V2312.0001). The affected applications contain a stack overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V2312.0001), Teamcenter Visualization V14.1 (Todas las versiones &lt; V14.1.0.13), Teamcenter Visualization V14.2 (Todas las versiones &lt; V14.2.0.10), Teamcenter Visualization V14.3 (Todas las versiones &lt; V14.3.0.7), Teamcenter Visualization V2312 (Todas las versiones &lt; V2312.0001). Las aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de pila al analizar archivos XML especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*","versionEndExcluding":"2312.0001","matchCriteriaId":"6DED9969-3AE9-4F11-B189-5762A519960E"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.1","versionEndExcluding":"14.1.0.13","matchCriteriaId":"C1FD4D8B-C0DB-4248-A48F-BEDCB8E9369D"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.2","versionEndExcluding":"14.2.0.10","matchCriteriaId":"B7554C26-5B51-4BE4-B09B-EC3A8684E8EC"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.3","versionEndExcluding":"14.3.0.7","matchCriteriaId":"F4911865-3EE2-4F5E-A92C-3974C272C3A9"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"2312.0","versionEndExcluding":"2312.0001","matchCriteriaId":"CCA43BAF-6754-4902-A04A-BF593ED7CDBA"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-661579.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-661579.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}