{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T08:28:35.567","vulnerabilities":[{"cve":{"id":"CVE-2024-32752","sourceIdentifier":"productsecurity@jci.com","published":"2024-06-06T21:15:48.523","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"The iSTAR door controllers running firmware prior to version 6.6.B, does not support authenticated\ncommunications with ICU, which may allow an attacker to gain unauthorized access"},{"lang":"es","value":"En determinadas circunstancias, las comunicaciones entre la herramienta ICU y un controlador de puerta iSTAR Pro son susceptibles a ataques Machine-in-the-Middle que podrían afectar el control y la configuración de la puerta."}],"metrics":{"cvssMetricV40":[{"source":"productsecurity@jci.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.2}]},"weaknesses":[{"source":"productsecurity@jci.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-158-04","source":"productsecurity@jci.com"},{"url":"https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories","source":"productsecurity@jci.com"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-158-04","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.johnsoncontrols.com/-/media/jci/cyber-solutions/product-security-advisories/2024/jci-psa-2024-06.pdf","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}