{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-30T04:24:49.963","vulnerabilities":[{"cve":{"id":"CVE-2024-32293","sourceIdentifier":"cve@mitre.org","published":"2024-04-17T14:15:09.113","lastModified":"2026-06-17T07:29:27.460","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function."},{"lang":"es","value":"El firmware Tenda W30E v1.0 V1.0.1.25(633) tiene una vulnerabilidad de desbordamiento de pila a través del parámetro de página en la función fromDhcpListClient."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","affectedData":[{"vendor":"tenda","product":"w30e_firmware","defaultStatus":"unknown","cpes":["cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"],"versions":[{"version":"1.0.1.25\\(633\\)","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.0,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2024-07-26T14:41:26.180586Z","id":"CVE-2024-32293","options":[{"exploitation":"poc"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*","matchCriteriaId":"535AF764-B5CF-44FA-89C6-2FDFFDCD0A32"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*","matchCriteriaId":"02FBE634-0D3F-4439-B4A6-F427C82967C7"}]}]}],"references":[{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromDhcpListClient_page.md","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromDhcpListClient_page.md","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}