{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-25T06:40:35.983","vulnerabilities":[{"cve":{"id":"CVE-2024-30211","sourceIdentifier":"secure@intel.com","published":"2025-02-12T22:15:32.587","lastModified":"2026-06-17T07:26:29.927","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Improper access control in some Intel(R) ME driver pack installer engines before version 2422.6.2.0 may allow an authenticated user to potentially enable escalation of privilege via local access."},{"lang":"es","value":"Un control de acceso inadecuado en algunos motores de instalación de paquetes de controladores Intel(R) ME anteriores a la versión 2422.6.2.0 puede permitir que un usuario autenticado habilite potencialmente la escalada de privilegios a través del acceso local."}],"affected":[{"source":"secure@intel.com","affectedData":[{"vendor":"n/a","product":"Intel(R) ME driver pack installer engines","defaultStatus":"unaffected","versions":[{"version":"before version 2422.6.2.0","status":"affected"}]}]}],"metrics":{"cvssMetricV40":[{"source":"secure@intel.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","attackRequirements":"PRESENT","privilegesRequired":"LOW","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"secure@intel.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N","baseScore":6.0,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":0.8,"impactScore":5.2}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-02-13T20:22:04.765529Z","id":"CVE-2024-30211","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"secure@intel.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]}],"references":[{"url":"https://intel.com/content/www/us/en/security-center/advisory/intel-sa-01152.html","source":"secure@intel.com"}]}}]}