{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T18:52:06.731","vulnerabilities":[{"cve":{"id":"CVE-2024-26275","sourceIdentifier":"productcert@siemens.com","published":"2024-04-09T09:15:24.260","lastModified":"2025-10-03T20:06:29.870","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT2Go (All versions < V2312.0004), Parasolid V35.1 (All versions < V35.1.254), Parasolid V36.0 (All versions < V36.0.207), Parasolid V36.1 (All versions < V36.1.147), Teamcenter Visualization V14.2 (All versions < V14.2.0.12), Teamcenter Visualization V14.3 (All versions < V14.3.0.9), Teamcenter Visualization V2312 (All versions < V2312.0004). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en JT2Go (Todas las versiones &lt; V2312.0004), Parasolid V35.1 (Todas las versiones &lt; V35.1.254), Parasolid V36.0 (Todas las versiones &lt; V36.0.207), Parasolid V36.1 (Todas las versiones &lt; V36.1.147), Teamcenter Visualization V14.2 (todas las versiones), Teamcenter Visualization V14.3 (todas las versiones &lt; V14.3.0.9), Teamcenter Visualization V2312 (todas las versiones &lt; V2312.0004). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada mientras analizan archivos X_T especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-125"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*","versionStartIncluding":"2312.0","versionEndExcluding":"2312.0004","matchCriteriaId":"30AC2F72-F744-4932-801A-76F82D4511B3"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.1","versionEndExcluding":"35.1.254","matchCriteriaId":"2C5B8DD7-F87C-4EAD-AF0E-6125A5017988"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"36.0","versionEndExcluding":"36.0.207","matchCriteriaId":"53F83A10-6FA3-477E-BE18-34AA39FB996D"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"36.1","versionEndExcluding":"36.1.147","matchCriteriaId":"B1E2DE94-EC81-4DDF-A545-31B1AAB3FC03"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.2","versionEndExcluding":"14.2.0.12","matchCriteriaId":"0973D930-AC79-48B1-A4A6-25F7734B5822"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"14.3","versionEndExcluding":"14.3.0.9","matchCriteriaId":"47FA9CED-27B4-4AF6-83B4-054E1FABC888"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*","versionStartIncluding":"2312.0","versionEndExcluding":"2312.0004","matchCriteriaId":"064B1ABE-247D-410F-A4E7-C428753DF69F"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-222019.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-771940.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-222019.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-771940.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}