{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-24T11:53:44.944","vulnerabilities":[{"cve":{"id":"CVE-2024-2602","sourceIdentifier":"cybersecurity@se.com","published":"2024-07-11T09:15:03.030","lastModified":"2024-11-21T09:10:05.910","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path\nTraversal') vulnerability exists that could result in remote code execution when an authenticated\nuser executes a saved project file that has been tampered by a malicious actor."},{"lang":"es","value":"CWE-22: Existe una vulnerabilidad de limitación inadecuada de un nombre de ruta a un directorio restringido (\"Path Traversal\") que podría provocar la ejecución remota de código cuando un usuario autenticado ejecuta un archivo de proyecto guardado que ha sido manipulado por un actor malintencionado."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.3,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:foxrtu_station:*:*:*:*:*:*:*:*","versionEndExcluding":"9.3.0","matchCriteriaId":"0C54753D-F3B9-4ED1-A8EF-F6C66561DD9E"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-03.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-03.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}