{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-25T06:32:48.876","vulnerabilities":[{"cve":{"id":"CVE-2024-23959","sourceIdentifier":"cve@asrg.io","published":"2024-09-28T07:15:03.367","lastModified":"2026-06-17T07:13:57.393","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Autel MaxiCharger AC Elite Business C50 BLE AppChargingControl Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Elite Business C50 charging stations. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of the AppChargingControl BLE command. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device.\n\nWas ZDI-CAN-23194"},{"lang":"es","value":"Vulnerabilidad de ejecución remota de código por desbordamiento de búfer basado en pila en el BLE AppChargingControl de Autel MaxiCharger AC Elite Business C50. Esta vulnerabilidad permite a los atacantes adyacentes a la red ejecutar código arbitrario en las instalaciones afectadas de las estaciones de carga Autel MaxiCharger AC Elite Business C50. Aunque se requiere autenticación para explotar esta vulnerabilidad, se puede omitir el mecanismo de autenticación existente. La falla específica existe en el manejo del comando AppChargingControl BLE. El problema es el resultado de la falta de una validación adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un búfer basado en pila de longitud fija. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del dispositivo. Era ZDI-CAN-23194"}],"affected":[{"source":"cve@asrg.io","affectedData":[{"vendor":"Autel","product":"MaxiCharger AC Elite Business C50","defaultStatus":"unknown","versions":[{"version":"1.32.00","status":"affected"}]}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","affectedData":[{"vendor":"autel","product":"maxicharger_ac_elite_business_c50_firmware","defaultStatus":"unknown","cpes":["cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:*:*:*:*:*:*:*:*"],"versions":[{"version":"0","lessThan":"1.35","versionType":"custom","status":"affected"}]},{"vendor":"autel","product":"maxicharger_ac_elite_business_c50_eu_firmware","defaultStatus":"unknown","cpes":["cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_eu_firmware:1.50:*:*:*:*:*:*:*"],"versions":[{"version":"0","lessThan":"1.50","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"cve@asrg.io","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.0,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.0,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2024-10-03T13:44:18.263961Z","id":"CVE-2024-23959","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"cve@asrg.io","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:autel:maxicharger_ac_elite_business_c50_firmware:1.32.00:*:*:*:*:*:*:*","matchCriteriaId":"8AE968C0-3E5C-4A7A-9687-C6D7208224E7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:autel:maxicharger_ac_elite_business_c50:-:*:*:*:*:*:*:*","matchCriteriaId":"5B2F9001-71B7-4B39-9114-FC54F4EAE9E7"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-24-851/","source":"cve@asrg.io","tags":["Third Party Advisory","VDB Entry"]}]}}]}