{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T16:15:51.714","vulnerabilities":[{"cve":{"id":"CVE-2024-23795","sourceIdentifier":"productcert@siemens.com","published":"2024-02-13T09:15:47.550","lastModified":"2024-11-21T08:58:26.150","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0012), Tecnomatix Plant Simulation V2302 (All versions < V2302.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones &lt; V2201.0012), Tecnomatix Plant Simulation V2302 (Todas las versiones &lt; V2302.0006). La aplicación afectada contiene una escritura fuera de los límites más allá del final de un búfer asignado mientras analiza un archivo WRL especialmente manipulado. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*","versionEndExcluding":"2201.0012","matchCriteriaId":"92315B86-671A-48F9-9D7D-C638DABD8520"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*","versionStartIncluding":"2302.0","versionEndExcluding":"2302.0006","matchCriteriaId":"D222D65A-C271-4BE4-8139-DB5F38D053D5"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-017796.html","source":"productcert@siemens.com","tags":["Mitigation","Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-017796.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Patch","Vendor Advisory"]}]}}]}