{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-15T01:51:55.306","vulnerabilities":[{"cve":{"id":"CVE-2024-23789","sourceIdentifier":"vultures@jpcert.or.jp","published":"2024-02-14T11:15:08.200","lastModified":"2025-12-23T21:47:38.570","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a network-adjacent unauthenticated attacker to execute an arbitrary OS command on the affected product."},{"lang":"es","value":"Energy Management Controller con servicios en la nube JH-RVB1 /JH-RV11 Ver.B0.1.9.1 y anteriores permite que un atacante no autenticado adyacente a la red ejecute un comando arbitrario del sistema operativo en el producto afectado."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:sharp:jh-rvb1_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"b0.1.9.1","matchCriteriaId":"B7EC16DF-21FB-473F-8F62-DDBF1C149A9B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:sharp:jh-rvb1:-:*:*:*:*:*:*:*","matchCriteriaId":"27ED2F7C-C3F1-41AA-81DA-3CD5C3B83F88"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:sharp:jh-rv11_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"b0.1.9.1","matchCriteriaId":"E0A2340C-A0BC-4DD5-A120-F7041D76D776"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:sharp:jh-rv11:-:*:*:*:*:*:*:*","matchCriteriaId":"9CF83BDB-56B1-4E80-91C3-AFAA96A0C25C"}]}]}],"references":[{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf","source":"vultures@jpcert.or.jp","tags":["Vendor Advisory"]},{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf","source":"vultures@jpcert.or.jp","tags":["Vendor Advisory"]},{"url":"https://jvn.jp/en/vu/JVNVU94591337/","source":"vultures@jpcert.or.jp","tags":["Third Party Advisory"]},{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://jvn.jp/en/vu/JVNVU94591337/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}