{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T01:15:50.523","vulnerabilities":[{"cve":{"id":"CVE-2024-23785","sourceIdentifier":"vultures@jpcert.or.jp","published":"2024-02-14T10:15:08.663","lastModified":"2024-11-21T08:58:23.857","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Cross-site request forgery vulnerability in Energy Management Controller with Cloud Services JH-RVB1 /JH-RV11 Ver.B0.1.9.1 and earlier allows a remote unauthenticated attacker to change the product settings."},{"lang":"es","value":"Vulnerabilidad de cross-site request forgery en Energy Management Controller con servicios en la nube JH-RVB1 /JH-RV11 Ver.B0.1.9.1 y anteriores permite que un atacante remoto no autenticado cambie la configuración del producto."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:L/A:L","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":2.7}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-352"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-352"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:sharp:jh-rvb1_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"b0.1.9.1","matchCriteriaId":"B7EC16DF-21FB-473F-8F62-DDBF1C149A9B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:sharp:jh-rvb1:*:*:*:*:*:*:*:*","matchCriteriaId":"AE2814EB-D067-4920-A450-4F90431EA461"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:sharp:jh-rv11_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"b0.1.9.1","matchCriteriaId":"E0A2340C-A0BC-4DD5-A120-F7041D76D776"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:sharp:jh-rv11:*:*:*:*:*:*:*:*","matchCriteriaId":"C13F6906-8ED6-40DE-8B18-260B7765C4A9"}]}]}],"references":[{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf","source":"vultures@jpcert.or.jp","tags":["Vendor Advisory"]},{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf","source":"vultures@jpcert.or.jp","tags":["Vendor Advisory"]},{"url":"https://jvn.jp/en/vu/JVNVU94591337/","source":"vultures@jpcert.or.jp","tags":["Third Party Advisory"]},{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_en.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://jp.sharp/support/taiyo/info/JVNVU94591337_jp.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://jvn.jp/en/vu/JVNVU94591337/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}