{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T14:36:17.947","vulnerabilities":[{"cve":{"id":"CVE-2024-22428","sourceIdentifier":"security_alert@emc.com","published":"2024-01-16T04:15:08.067","lastModified":"2024-11-21T08:56:16.260","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nDell iDRAC Service Module, versions 5.2.0.0 and prior, contain an Incorrect Default Permissions vulnerability. It may allow a local unprivileged user to escalate privileges and execute arbitrary code on the affected system. Dell recommends customers upgrade at the earliest opportunity.\n\n"},{"lang":"es","value":"Dell iDRAC Service Module, versiones 5.2.0.0 y anteriores, contiene una vulnerabilidad de permisos predeterminados incorrectos. Puede permitir que un usuario local sin privilegios escale privilegios y ejecute código arbitrario en el sistema afectado. Dell recomienda a los clientes actualizar lo antes posible."}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.0,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.0,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-276"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-276"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:dell:emc_idrac_service_module:*:*:*:*:*:*:*:*","versionEndIncluding":"5.2.0.0","matchCriteriaId":"CF8A2D97-2E01-4726-9C55-640B7CA80314"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000221129/dsa-2024-018-security-update-for-dell-idrac-service-module-for-weak-folder-permission-vulnerabilities","source":"security_alert@emc.com","tags":["Vendor Advisory"]},{"url":"https://www.dell.com/support/kbdoc/en-us/000221129/dsa-2024-018-security-update-for-dell-idrac-service-module-for-weak-folder-permission-vulnerabilities","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}