{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-08T01:15:17.570","vulnerabilities":[{"cve":{"id":"CVE-2024-21794","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2024-02-02T00:15:54.953","lastModified":"2024-11-21T08:55:00.990","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Rapid Software LLC's Rapid SCADA versions prior to Version 5.8.4, an attacker can redirect users to malicious pages through the login page.\n"},{"lang":"es","value":"En las versiones Rapid SCADA de Rapid Software LLC anteriores a la versión 5.8.4, un atacante puede redirigir a los usuarios a páginas maliciosas a través de la página de inicio de sesión."}],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:L","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.3,"impactScore":2.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:L","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.3,"impactScore":2.7}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-601"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-601"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rapidscada:rapid_scada:*:*:*:*:*:*:*:*","versionEndIncluding":"5.8.4","matchCriteriaId":"280A83B5-F3B4-4BA0-A112-A5FC00D74091"}]}]}],"references":[{"url":"https://rapidscada.org/contact/","source":"ics-cert@hq.dhs.gov","tags":["Product"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-011-03","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://rapidscada.org/contact/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Product"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-011-03","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}