{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-07T13:22:13.326","vulnerabilities":[{"cve":{"id":"CVE-2024-21483","sourceIdentifier":"productcert@siemens.com","published":"2024-03-12T11:15:48.217","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)), SENTRON 7KM PAC3220 DC (7KM3220-1BA01-1EA0) (All versions >= V3.2.3 < V3.2.4 only when manufactured between LQN231003... and LQN231215... ( with LQNYYMMDD...)). The read out protection of the internal flash of affected devices was not properly set at the end of the manufacturing process.\r\n\r\nAn attacker with physical access to the device could read out the data."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SENTRON 7KM PAC3120 AC/DC (7KM3120-0BA01-1DA0) (Todas las versiones &gt;= V3.2.3 &lt; V3.3.0 sólo cuando se fabrican entre LQN231003... y LQN231215... ( con LQNYYMMDD... )), SENTRON 7KM PAC3120 DC (7KM3120-1BA01-1EA0) (Todas las versiones &gt;= V3.2.3 &lt; V3.3.0 solo cuando se fabrican entre LQN231003... y LQN231215... (con LQNYYMMDD...)), SENTRON 7KM PAC3220 AC/DC (7KM3220-0BA01-1DA0) (Todas las versiones &gt;= V3.2.3 &lt; V3.3.0 solo cuando se fabrican entre LQN231003... y LQN231215... (con LQNYYMMDD...)), SENTRON 7KM PAC3220 DC ( 7KM3220-1BA01-1EA0) (Todas las versiones &gt;= V3.2.3 &lt; V3.3.0 solo cuando se fabrican entre LQN231003... y LQN231215... (con LQNYYMMDD...)). La protección de lectura del flash interno de los dispositivos afectados no se configuró correctamente al final del proceso de fabricación. Un atacante con acceso físico al dispositivo podría leer los datos."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.1,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":4.6,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.9,"impactScore":3.6}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-792319.html","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-792319.html","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}