{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T07:39:26.830","vulnerabilities":[{"cve":{"id":"CVE-2023-7032","sourceIdentifier":"cybersecurity@se.com","published":"2024-01-09T20:15:42.967","lastModified":"2024-11-21T08:45:05.137","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker\nlogged in with a user level account to gain higher privileges by providing a harmful serialized\nobject.\n\n"},{"lang":"es","value":"Existe una vulnerabilidad CWE-502: deserialización de datos no confiables que podría permitir que un atacante que haya iniciado sesión con una cuenta de nivel de usuario obtenga mayores privilegios al proporcionar un objeto serializado dañino."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-502"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:easergy_studio:*:*:*:*:*:*:*:*","versionEndIncluding":"9.3.5","matchCriteriaId":"97EFDB27-39E0-4D76-BAB7-20D59CB364B8"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-009-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-009-02.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-009-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-009-02.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}