{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T15:52:16.109","vulnerabilities":[{"cve":{"id":"CVE-2023-6926","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2024-01-23T20:15:45.233","lastModified":"2024-11-21T08:44:50.977","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nThere is an OS command injection vulnerability in Crestron AM-300 firmware version 1.4499.00018 which may enable a user of a limited-access SSH session to escalate their privileges to root-level access.\n\n"},{"lang":"es","value":"Existe una vulnerabilidad de inyección de comandos del sistema operativo en la versión 1.4499.00018 del firmware Crestron AM-300 que puede permitir a un usuario de una sesión SSH de acceso limitado escalar sus privilegios al acceso de nivel root."}],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.5,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:crestron:am-300_firmware:1.4499.00018:*:*:*:*:*:*:*","matchCriteriaId":"3E71A698-2505-4C86-A2B0-161C051AC573"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:crestron:am-300:-:*:*:*:*:*:*:*","matchCriteriaId":"D2A0894F-6D87-40C4-B386-99A31034ADDF"}]}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-023-02","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-24-023-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}