{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-27T22:08:07.142","vulnerabilities":[{"cve":{"id":"CVE-2023-6409","sourceIdentifier":"cybersecurity@se.com","published":"2024-02-14T17:15:11.247","lastModified":"2024-12-11T19:33:54.427","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"\nCWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized\naccess to a project file protected with application password when opening the file with\nEcoStruxure Control Expert.\n\n"},{"lang":"es","value":"CWE-798: Existe una vulnerabilidad de uso de credenciales codificadas que podría causar acceso no autorizado a un archivo de proyecto protegido con contraseña de aplicación al abrir el archivo con EcoStruxure Control Expert."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":7.7,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.5,"impactScore":5.2},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":7.7,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.5,"impactScore":5.2}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-798"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"16.0","matchCriteriaId":"1FF68269-FEB0-41F0-9127-965AA4ADCC91"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*","versionEndExcluding":"2023","matchCriteriaId":"D8022AED-42C4-42F5-A30A-45F157D71CA9"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}