{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T15:14:38.428","vulnerabilities":[{"cve":{"id":"CVE-2023-5391","sourceIdentifier":"cybersecurity@se.com","published":"2023-10-04T19:15:10.777","lastModified":"2024-11-21T08:41:40.707","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\n\n\nA CWE-502: Deserialization of untrusted data vulnerability exists that could allow an attacker to\nexecute arbitrary code on the targeted system by sending a specifically crafted packet to the\napplication.\n\n\n\n\n"},{"lang":"es","value":"CWE-502: Existe una vulnerabilidad deserialización de datos no confiables que podría permitir a un atacante ejecutar código arbitrario en el sistema objetivo enviando un paquete específicamente manipulado a la aplicación."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-502"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*","matchCriteriaId":"B682ECD9-985F-4906-B936-DD388165063A"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_operation_with_advanced_reports:*:*:*:*:*:*:*:*","matchCriteriaId":"8A9E16D1-278E-4E0B-A604-13096B7A9029"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_power_scada_operation_with_advanced_reports:*:*:*:*:*:*:*:*","matchCriteriaId":"DC4A71CF-78EA-43F9-B7BA-9ED3C7816173"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-283-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-283-02.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}