{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T11:43:03.541","vulnerabilities":[{"cve":{"id":"CVE-2023-51585","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2024-05-03T03:16:18.547","lastModified":"2025-07-09T16:58:50.287","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Voltronic Power ViewPower USBCommEx shutdown Command Injection Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation.\n\nThe specific flaw exists within the shutdown method. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22071."},{"lang":"es","value":"Voltronic Power ViewPower USBCommEx apagado Inyección de comandos Vulnerabilidad de ejecución remota de código. Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en instalaciones afectadas de Voltronic Power ViewPower Pro. Se requiere la interacción del usuario para aprovechar esta vulnerabilidad, ya que un administrador debe activar una operación de apagado. La falla específica existe dentro del método de apagado. El problema se debe a la falta de validación adecuada de una cadena proporcionada por el usuario antes de usarla para ejecutar una llamada al sistema. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del usuario actual. Era ZDI-CAN-22071."}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:voltronicpower:viewpower:1.04.21353:*:*:*:-:*:*:*","matchCriteriaId":"2CE4A520-86B5-4AE3-AD0E-7744328090E4"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1890/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1890/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}