{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T11:48:25.891","vulnerabilities":[{"cve":{"id":"CVE-2023-51577","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2024-05-03T03:16:17.143","lastModified":"2025-07-09T17:01:29.157","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Voltronic Power ViewPower setShutdown Exposed Dangerous Method Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Voltronic Power ViewPower. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the setShutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22023."},{"lang":"es","value":"Voltronic Power ViewPower setShutdown Método peligroso expuesto Vulnerabilidad de escalada de privilegios locales. Esta vulnerabilidad permite a atacantes locales escalar privilegios en las instalaciones afectadas de Voltronic Power ViewPower. Un atacante primero debe obtener la capacidad de ejecutar código con pocos privilegios en el sistema de destino para poder explotar esta vulnerabilidad. La falla específica existe dentro del método setShutdown. El problema se debe a un método peligroso expuesto. Un atacante puede aprovechar esta vulnerabilidad para escalar privilegios y ejecutar código arbitrario en el contexto de SYSTEM. Era ZDI-CAN-22023."}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-749"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:voltronicpower:viewpower:1.04.21353:*:*:*:-:*:*:*","matchCriteriaId":"2CE4A520-86B5-4AE3-AD0E-7744328090E4"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1883/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1883/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}