{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-05T16:08:16.616","vulnerabilities":[{"cve":{"id":"CVE-2023-51575","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2024-05-03T03:16:16.747","lastModified":"2025-07-09T16:56:43.237","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Voltronic Power ViewPower MonitorConsole Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the MonitorConsole class. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22011."},{"lang":"es","value":"Voltronic Power ViewPower MonitorConsole expuso una vulnerabilidad de ejecución remota de código de método peligroso. Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en las instalaciones afectadas de Voltronic Power ViewPower. No se requiere autenticación para aprovechar esta vulnerabilidad. La falla específica existe dentro de la clase MonitorConsole. El problema se debe a un método peligroso expuesto. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del usuario actual. Fue ZDI-CAN-22011."}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-749"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:voltronicpower:viewpower:1.04.21353:*:*:*:-:*:*:*","matchCriteriaId":"2CE4A520-86B5-4AE3-AD0E-7744328090E4"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1881/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1881/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}