{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-30T14:05:53.219","vulnerabilities":[{"cve":{"id":"CVE-2023-49693","sourceIdentifier":"vulnreport@tenable.com","published":"2023-11-29T23:15:20.567","lastModified":"2026-06-17T06:36:19.327","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nNETGEAR ProSAFE Network Management System has Java Debug Wire Protocol (JDWP) listening on port 11611 and it is remotely accessible by unauthenticated users, allowing attackers to execute arbitrary code.\n\n"},{"lang":"es","value":"NETGEAR ProSAFE Network Management System tiene Java Debug Wire Protocol (JDWP) escuchando en el puerto 11611 y usuarios no autenticados pueden acceder a él de forma remota, lo que permite a los atacantes ejecutar código arbitrario."}],"affected":[{"source":"vulnreport@tenable.com","affectedData":[{"vendor":"NETGEAR","product":"NETGEAR ProSAFE Network Management System","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"1.7.0.34","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"vulnreport@tenable.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"vulnreport@tenable.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:netgear:prosafe_network_management_system:*:*:*:*:*:*:*:*","versionEndExcluding":"1.7.0.34","matchCriteriaId":"910077CB-66F7-44DC-8FD8-0CE742C16AA4"}]}]}],"references":[{"url":"https://kb.netgear.com/000065886/Security-Advisory-for-Sensitive-Information-Disclosure-on-the-NMS300-PSV-2023-0126","source":"vulnreport@tenable.com","tags":["Vendor Advisory"]},{"url":"https://www.tenable.com/security/research/tra-2023-39","source":"vulnreport@tenable.com","tags":["Exploit","Third Party Advisory"]},{"url":"https://kb.netgear.com/000065886/Security-Advisory-for-Sensitive-Information-Disclosure-on-the-NMS300-PSV-2023-0126","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.tenable.com/security/research/tra-2023-39","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}