{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T11:14:13.259","vulnerabilities":[{"cve":{"id":"CVE-2023-46717","sourceIdentifier":"psirt@fortinet.com","published":"2024-03-12T15:15:46.487","lastModified":"2024-11-21T08:29:08.597","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An improper authentication vulnerability [CWE-287] in FortiOS versions 7.4.1 and below, versions 7.2.6 and below, and versions 7.0.12 and below when configured with FortiAuthenticator in HA may allow a readonly user to gain read-write access via successive login attempts."},{"lang":"es","value":"Una vulnerabilidad de autenticación incorrecta [CWE-287] en las versiones 7.4.1 y anteriores de FortiOS, las versiones 7.2.6 y siguientes y las versiones 7.0.12 y siguientes cuando se configura con FortiAuthenticator en HA puede permitir que un usuario de solo lectura obtenga acceso de lectura y escritura a través de intentos sucesivos de inicio de sesión."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.6,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.0.0","versionEndExcluding":"7.0.13","matchCriteriaId":"D25F9C04-C7FD-4B1F-A194-CA69E5DE903C"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.2.0","versionEndExcluding":"7.2.7","matchCriteriaId":"553C4BA9-953B-4017-8498-785BDA7A3006"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.4.0","versionEndExcluding":"7.4.2","matchCriteriaId":"4316C2EA-3D6E-4A0C-B81D-ADCE040E03E0"}]}]}],"references":[{"url":"https://fortiguard.com/psirt/FG-IR-23-424","source":"psirt@fortinet.com","tags":["Vendor Advisory"]},{"url":"https://fortiguard.com/psirt/FG-IR-23-424","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}