{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T10:39:32.414","vulnerabilities":[{"cve":{"id":"CVE-2023-46289","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2023-10-27T19:15:41.493","lastModified":"2024-11-21T08:28:14.307","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nRockwell Automation FactoryTalk View Site Edition insufficiently validates user input, which could potentially allow threat actors to send malicious data bringing the product offline. If exploited, the product would become unavailable and require a restart to recover resulting in a denial-of-service condition.\n\n"},{"lang":"es","value":"Rockwell Automation FactoryTalk View Site Edition no valida suficientemente la entrada del usuario, lo que podría permitir que los actores de amenazas envíen datos maliciosos y desconecten el producto. Si se explota, el producto dejaría de estar disponible y requeriría un reinicio para recuperarse, lo que provocaría una condición de Denegación de Servicio (DoS)."}],"metrics":{"cvssMetricV31":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:factorytalk_view:*:*:*:*:site_edition:*:*:*","versionStartIncluding":"11.0","versionEndIncluding":"13.0","matchCriteriaId":"F6E450A8-F513-496F-A9D6-059A0987F543"}]}]}],"references":[{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167","source":"PSIRT@rockwellautomation.com","tags":["Permissions Required","Vendor Advisory"]},{"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1141167","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Vendor Advisory"]}]}}]}