{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-15T02:53:35.387","vulnerabilities":[{"cve":{"id":"CVE-2023-45844","sourceIdentifier":"psirt@bosch.com","published":"2023-10-25T18:17:35.347","lastModified":"2024-11-21T08:27:28.350","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The vulnerability allows a low privileged user that have access to the device when locked in Kiosk mode to install an arbitrary Android application and leverage it to have access to critical device settings such as the device power management or eventually the device secure settings (ADB debug)."},{"lang":"es","value":"La vulnerabilidad permite a un usuario con pocos privilegios que tiene acceso al dispositivo cuando está bloqueado en modo quiosco instalar una aplicación Android arbitraria y aprovecharla para tener acceso a configuraciones críticas del dispositivo, como la administración de energía del dispositivo o, eventualmente, la configuración segura del dispositivo (depuración ADB). ."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.9,"impactScore":5.9}],"cvssMetricV30":[{"source":"psirt@bosch.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:P/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.7,"impactScore":6.0}]},"weaknesses":[{"source":"psirt@bosch.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2107_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"7FFA1309-DBEE-46F1-B6FD-DAE896180411"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2107:-:*:*:*:*:*:*:*","matchCriteriaId":"87C129B8-F100-4D3A-97BC-BAD9A4129F9D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2110_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"FD47D2E3-F53F-4CE8-BEF7-76F78AEBAF5C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2110:-:*:*:*:*:*:*:*","matchCriteriaId":"326E80AA-C9B4-4BF1-AA2B-98A3802A72C9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:boschrexroth:ctrlx_hmi_web_panel_wr2115_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"4CA92486-EEBE-42FD-9755-006B7F2DF361"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:boschrexroth:ctrlx_hmi_web_panel_wr2115:-:*:*:*:*:*:*:*","matchCriteriaId":"167C9BC4-FCC5-4FAF-8F75-F967C77400A7"}]}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","source":"psirt@bosch.com","tags":["Mitigation","Vendor Advisory"]},{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-175607.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Vendor Advisory"]}]}}]}