{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T17:30:25.449","vulnerabilities":[{"cve":{"id":"CVE-2023-45204","sourceIdentifier":"productcert@siemens.com","published":"2023-10-10T11:15:13.080","lastModified":"2024-11-21T08:26:32.767","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0009), Tecnomatix Plant Simulation V2302 (All versions < V2302.0003). The affected applications contain a type confusion vulnerability while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process.  (ZDI-CAN-21268)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en: \nTecnomatix Plant Simulation V2201 (Todas las versiones &lt; V2201.0009),\nTecnomatix Plant Simulation V2302 (Todas las versiones &lt; V2302.0003). \nLas aplicaciones afectadas contienen una vulnerabilidad de confusión de tipos al analizar archivos IGS especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-21268)"}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-704"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*","versionStartIncluding":"2201","versionEndExcluding":"2201.0009","matchCriteriaId":"ECCC6F17-BB3D-4FD0-B277-5DD86EB4C9F7"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*","versionStartIncluding":"2302","versionEndExcluding":"2302.0003","matchCriteriaId":"C29307AD-B728-41D3-9D57-FD5D1D51ACFA"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-524778.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}