{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T11:01:41.412","vulnerabilities":[{"cve":{"id":"CVE-2023-4516","sourceIdentifier":"cybersecurity@se.com","published":"2023-09-14T09:15:08.610","lastModified":"2024-11-21T08:35:19.940","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"},{"lang":"es","value":"Existe una vulnerabilidad \"CWE-306: Autenticación Faltante para Funciones Críticas\" en el servicio de actualización IGSS que podría permitir a un atacante local cambiar la fuente de actualización, lo que podría provocar la ejecución remota de código cuando el atacante fuerce una actualización que contenga contenido malicioso."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionEndIncluding":"16.0.0.23211","matchCriteriaId":"93B0387C-D40E-446F-AD55-4214804A0B4D"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}