{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-11T02:50:38.652","vulnerabilities":[{"cve":{"id":"CVE-2023-44315","sourceIdentifier":"productcert@siemens.com","published":"2023-10-10T11:15:12.993","lastModified":"2024-11-21T08:25:39.047","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC NMS (All versions < V2.0). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could prepare a stored cross-site scripting (XSS) attack that may lead to unintentional modification of application data by legitimate users."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEC NMS (Todas las versiones &lt; V2.0). La aplicación afectada sanitiza incorrectamente ciertos datos de configuración SNMP recuperados de los dispositivos monitorizados. Un atacante con acceso a un dispositivo monitorizado podría preparar un ataque de Cross-Site Scripting (XSS) almacenado que puede llevar a la modificación no intencionada de los datos de la aplicación por parte de usuarios legítimos."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":4.7,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.6,"impactScore":2.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":2.7}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*","versionEndExcluding":"2.0","matchCriteriaId":"A7F0A543-38E1-48B9-A984-259081E49EAA"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-160243.html","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-160243.html","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-160243.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}