{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T08:04:11.080","vulnerabilities":[{"cve":{"id":"CVE-2023-43699","sourceIdentifier":"psirt@sick.de","published":"2023-10-09T12:15:10.140","lastModified":"2024-11-21T08:24:35.850","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nImproper Restriction of Excessive Authentication Attempts in RDT400 in SICK APU\nallows an unprivileged remote attacker to guess the password via trial-and-error as the login attempts\nare not limited.\n\n"},{"lang":"es","value":"La restricción inadecuada de intentos de autenticación excesivos de RDT400 en SICK APU permite a un atacante remoto sin privilegios adivinar la contraseña mediante prueba y error, ya que los intentos de inicio de sesión no están limitados."}],"metrics":{"cvssMetricV31":[{"source":"psirt@sick.de","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"psirt@sick.de","type":"Secondary","description":[{"lang":"en","value":"CWE-307"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-307"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:sick:apu0200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.0.0.6","matchCriteriaId":"B2A3C873-A9B5-4AF8-8703-F00233E56A5E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:sick:apu0200:-:*:*:*:*:*:*:*","matchCriteriaId":"0E32F3FD-FB2B-4F73-AD20-8AB98B02FCF1"}]}]}],"references":[{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0010.json","source":"psirt@sick.de","tags":["Vendor Advisory"]},{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0010.pdf","source":"psirt@sick.de","tags":["Vendor Advisory"]},{"url":"https://sick.com/psirt","source":"psirt@sick.de","tags":["Product"]},{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0010.json","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://sick.com/.well-known/csaf/white/2023/sca-2023-0010.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://sick.com/psirt","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Product"]}]}}]}