{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T15:01:36.860","vulnerabilities":[{"cve":{"id":"CVE-2023-42797","sourceIdentifier":"productcert@siemens.com","published":"2024-01-09T10:15:15.320","lastModified":"2024-11-21T08:23:10.517","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.20), CP-8050 MASTER MODULE (All versions < CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps.\r\n\r\nBy uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en CP-8031 MASTER MODULE (Todas las versiones &lt; CPCI85 V05.20), CP-8050 MASTER MODULE (Todas las versiones &lt; CPCI85 V05.20). El servicio de configuración de red de los dispositivos afectados contiene un fallo en la conversión de direcciones IPv4 que podría llevar a que se utilice una variable no inicializada en los siguientes pasos de validación. Al cargar una configuración de red especialmente manipulada, un atacante remoto autenticado podría inyectar comandos que se ejecutan en el dispositivo con privilegios de root durante el inicio del dispositivo."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.6,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.7,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-908"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sicam_a8000_cp-8050_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"05.20","matchCriteriaId":"F6EB6432-1779-4083-BE80-3C1A6B4BE637"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sicam_a8000_cp-8050:-:*:*:*:*:*:*:*","matchCriteriaId":"FC600085-2164-43DD-90D6-892EC31432E0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sicam_a8000_cp-8031_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"05.20","matchCriteriaId":"A35CE504-A034-463E-B4DC-6C91D72C0E1D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sicam_a8000_cp-8031:-:*:*:*:*:*:*:*","matchCriteriaId":"460D8D7D-A0DF-4828-B2AC-ECD6DB1DAA4A"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-583634.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-583634.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}