{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-02T04:16:01.997","vulnerabilities":[{"cve":{"id":"CVE-2023-41838","sourceIdentifier":"psirt@fortinet.com","published":"2023-10-10T17:15:12.743","lastModified":"2024-11-21T08:21:46.483","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An improper neutralization of special elements used in an os command ('os command injection') in FortiManager 7.4.0 and 7.2.0 through 7.2.3 may allow attacker to execute unauthorized code or commands via FortiManager cli."},{"lang":"es","value":"Una neutralización inadecuada de elementos especiales utilizados en un comando del sistema operativo ('inyección de comando del sistema operativo') en FortiManager 7.4.0 y 7.2.0 a 7.2.3 puede permitir que un atacante ejecute código o comandos no autorizados a través de FortiManager cli."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.2},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.2}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*","versionStartIncluding":"6.2.0","versionEndIncluding":"6.2.11","matchCriteriaId":"AB37EC26-3458-4AB4-91E5-58B75E587F64"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*","versionStartIncluding":"6.4.0","versionEndIncluding":"6.4.12","matchCriteriaId":"041E0C3F-E9B6-46E3-87D4-718FAC0C024E"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*","versionStartIncluding":"7.0.0","versionEndIncluding":"7.0.8","matchCriteriaId":"8B74F415-4705-4923-945F-CB393326F78D"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:*:*:*:*:*:*:*:*","versionStartIncluding":"7.2.0","versionEndIncluding":"7.2.3","matchCriteriaId":"B31BB84A-E622-4911-AAB4-41E57F661A8D"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortianalyzer:7.4.0:*:*:*:*:*:*:*","matchCriteriaId":"91A9AF01-72FD-4942-A95E-71A7609B6977"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*","versionStartIncluding":"6.2.0","versionEndIncluding":"6.2.11","matchCriteriaId":"67777F42-09E1-4651-807C-325A5F0D8A66"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*","versionStartIncluding":"6.4.0","versionEndIncluding":"6.4.12","matchCriteriaId":"0FC51DD4-5232-41CD-B85A-8AF8DB74A322"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*","versionStartIncluding":"7.0.0","versionEndIncluding":"7.0.8","matchCriteriaId":"7AEFC8D4-6358-4A81-BCF3-D162871F59F1"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortimanager:*:*:*:*:*:*:*:*","versionStartIncluding":"7.2.0","versionEndIncluding":"7.2.3","matchCriteriaId":"7C7C73B7-2AE1-4FC2-A37A-89A085796D19"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortimanager:7.4.0:*:*:*:*:*:*:*","matchCriteriaId":"DBBF7219-D15F-43C9-9A90-1A4B062431E4"}]}]}],"references":[{"url":"https://fortiguard.com/psirt/FG-IR-23-169","source":"psirt@fortinet.com","tags":["Vendor Advisory"]},{"url":"https://fortiguard.com/psirt/FG-IR-23-169","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}