{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-21T09:52:17.447","vulnerabilities":[{"cve":{"id":"CVE-2023-41562","sourceIdentifier":"cve@mitre.org","published":"2023-08-30T13:15:14.573","lastModified":"2026-06-17T06:22:24.820","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet."},{"lang":"es","value":"Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, y Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 se descubrió que contenían un desbordamiento de pila a través del parámetro time en la URL /goform/PowerSaveSet."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","affectedData":[{"vendor":"tenda","product":"ac7","defaultStatus":"unknown","cpes":["cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*"],"versions":[{"version":"1.0_v15.03.06.44","status":"affected"}]},{"vendor":"tenda","product":"ac9","defaultStatus":"unknown","cpes":["cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*"],"versions":[{"version":"3.0_v15.03.06.42_multi","status":"affected"}]},{"vendor":"tenda","product":"ac5","defaultStatus":"unknown","cpes":["cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*"],"versions":[{"version":"1.0rtl_v15.03.06.28","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2024-10-01T18:52:45.696202Z","id":"CVE-2023-41562","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*","matchCriteriaId":"7AE11228-D2BB-48CF-BFDA-E2AA73E73C3C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*","matchCriteriaId":"7F482F89-B0F6-450D-B675-43EC0A9E6A4B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*","matchCriteriaId":"4D94B37C-491D-4E7C-8273-F46FEDA62C9F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*","matchCriteriaId":"96503617-6B69-4862-ADFE-4EF379876F0F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*","matchCriteriaId":"7F928648-C8B2-4D37-8343-C74AABEFAB07"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*","matchCriteriaId":"D141716B-56F0-4061-9D87-943B7858F2F4"}]}]}],"references":[{"url":"https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://github.com/peris-navince/founded-0-days/blob/main/setSmartPowerManagement/1.md","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}