{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T17:11:25.975701400Z","vulnerabilities":[{"cve":{"id":"CVE-2023-41033","sourceIdentifier":"productcert@siemens.com","published":"2023-09-12T10:15:29.783","lastModified":"2024-11-21T08:20:25.450","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Parasolid V35.0 (All versions < V35.0.260), Parasolid V35.1 (All versions < V35.1.246), Parasolid V36.0 (All versions < V36.0.156), Simcenter Femap V2301 (All versions < V2301.0003), Simcenter Femap V2306 (All versions < V2306.0001). The affected application contains an out of bounds write past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21266)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Parasolid V35.0 (todas las versiones &lt; V35.0.260), Parasolid V35.1 (todas las versiones &lt; V35.1.246), Parasolid V36.0 (todas las versiones &lt; V36.0.156). La aplicación afectada contiene una escritura fuera de los límites más allá del final de una estructura asignada mientras analiza archivos X_T especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-21266)"}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.0","versionEndExcluding":"35.0.260","matchCriteriaId":"A15581E8-5B1C-4FA3-8416-A51832018B2A"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"35.1","versionEndExcluding":"35.1.246","matchCriteriaId":"030986EF-744F-476B-BAB1-BCE12D456C5F"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:parasolid:*:*:*:*:*:*:*:*","versionStartIncluding":"36.0","versionEndExcluding":"36.0.156","matchCriteriaId":"2B357683-F73D-47E7-9750-95D1018D035B"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*","versionStartIncluding":"2301.0","versionEndExcluding":"2301.0003","matchCriteriaId":"FC710071-C7AC-4ED0-9550-5FBE8FCD37AE"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simcenter_femap:*:*:*:*:*:*:*:*","versionStartIncluding":"2306.0","versionEndExcluding":"2306.0001","matchCriteriaId":"8E84C2D3-EF31-46E9-884A-7EB00B515D23"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-190839.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-887122.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}