{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T11:31:51.020","vulnerabilities":[{"cve":{"id":"CVE-2023-40714","sourceIdentifier":"psirt@fortinet.com","published":"2025-04-02T08:15:13.530","lastModified":"2025-07-15T19:41:08.467","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A relative path traversal in Fortinet FortiSIEM versions 7.0.0, 6.7.0 through 6.7.2, 6.6.0 through 6.6.3, 6.5.1, 6.5.0 allows attacker to escalate privilege via uploading certain GUI elements"},{"lang":"es","value":"Un Path Traversal relativo en las versiones 7.0.0, 6.7.0 a 6.7.2, 6.6.0 a 6.6.3, 6.5.1 y 6.5.0 de Fortinet FortiSIEM permite a un atacante escalar privilegios mediante la carga de ciertos elementos de la GUI."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.1,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-23"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisiem:*:*:*:*:*:*:*:*","versionStartIncluding":"6.4.0","versionEndIncluding":"6.5.1","matchCriteriaId":"C994856C-4130-466C-AF0E-B82E170E1781"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisiem:*:*:*:*:*:*:*:*","versionStartIncluding":"6.6.0","versionEndIncluding":"6.6.3","matchCriteriaId":"EB301503-0ECB-4D21-B341-ACF0F302CF85"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisiem:*:*:*:*:*:*:*:*","versionStartIncluding":"6.7.0","versionEndIncluding":"6.7.3","matchCriteriaId":"793796C9-C300-4737-8275-52299FACAC21"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisiem:7.0.0:*:*:*:*:*:*:*","matchCriteriaId":"CAB28BA6-45B6-422B-9901-300B6024F703"}]}]}],"references":[{"url":"https://fortiguard.com/psirt/FG-IR-23-085","source":"psirt@fortinet.com","tags":["Vendor Advisory"]}]}}]}