{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T18:06:46.229","vulnerabilities":[{"cve":{"id":"CVE-2023-39509","sourceIdentifier":"psirt@bosch.com","published":"2023-12-18T13:15:07.210","lastModified":"2024-11-21T08:15:33.903","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A command injection vulnerability exists in Bosch IP cameras that allows an authenticated user with administrative rights to run arbitrary commands on the OS of the camera."},{"lang":"es","value":"Existe una vulnerabilidad de inyección de comandos en las cámaras IP de Bosch que permite a un usuario autenticado con derechos administrativos ejecutar comandos arbitrarios en el sistema operativo de la cámara."}],"metrics":{"cvssMetricV31":[{"source":"psirt@bosch.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}]},"weaknesses":[{"source":"psirt@bosch.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-77"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:bosch:cpp13_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"8.90","matchCriteriaId":"76747B70-CBD6-4072-A9C7-EB89017494E9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:bosch:cpp13:-:*:*:*:*:*:*:*","matchCriteriaId":"80149FF9-3C6D-4C80-8257-CEB2BE8B0DCA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:bosch:cpp14_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"8.20","versionEndIncluding":"8.81","matchCriteriaId":"5233DED6-3919-42BB-ABE0-1907AB33F232"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:bosch:cpp14:-:*:*:*:*:*:*:*","matchCriteriaId":"B7872B92-4708-4522-BA8F-5BE941D169AC"}]}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html","source":"psirt@bosch.com","tags":["Vendor Advisory"]},{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-638184-BT.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}