{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T14:47:20.373","vulnerabilities":[{"cve":{"id":"CVE-2023-39459","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2024-05-03T03:15:10.987","lastModified":"2025-06-17T21:03:44.860","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Triangle MicroWorks SCADA Data Gateway Directory Traversal Arbitrary File Creation Vulnerability. This vulnerability allows remote attackers to create arbitrary files on affected installations of Triangle MicroWorks SCADA Data Gateway. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the processing of workspace files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to create files in the context of Administrator. Was ZDI-CAN-20531."},{"lang":"es","value":"Vulnerabilidad de creación de archivos arbitrarios Directory Traversal de puerta de enlace de datos SCADA de Triangle MicroWorks. Esta vulnerabilidad permite a atacantes remotos crear archivos arbitrarios en las instalaciones afectadas de Triangle MicroWorks SCADA Data Gateway. Se requiere la interacción del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una página maliciosa o abrir un archivo malicioso. La falla específica existe en el procesamiento de archivos del espacio de trabajo. El problema se debe a la falta de validación adecuada de una ruta proporcionada por el usuario antes de usarla en operaciones de archivos. Un atacante puede aprovechar esta vulnerabilidad para crear archivos en el contexto del Administrador. Era ZDI-CAN-20531."}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:trianglemicroworks:scada_data_gateway:5.1.3:*:*:*:*:*:*:*","matchCriteriaId":"E52553E2-31EB-48D8-AB17-167CE092FB8C"}]}]}],"references":[{"url":"https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new","source":"zdi-disclosures@trendmicro.com","tags":["Release Notes"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1027/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]},{"url":"https://www.trianglemicroworks.com/products/scada-data-gateway/what's-new","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Release Notes"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-1027/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}