{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-02T12:19:27.219","vulnerabilities":[{"cve":{"id":"CVE-2023-39256","sourceIdentifier":"security_alert@emc.com","published":"2023-12-02T05:15:07.793","lastModified":"2024-11-21T08:15:00.260","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nDell Rugged Control Center, version prior to 4.7, contains an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability to modify the content in an unsecured folder during product installation and upgrade, leading to privilege escalation on the system.\n\n"},{"lang":"es","value":"Dell Rugged Control Center, versión anterior a 4.7, contiene una vulnerabilidad de control de acceso inadecuado. Un usuario estándar malicioso local podría explotar esta vulnerabilidad para modificar el contenido de una carpeta no segura durante la instalación y actualización del producto, lo que provocaría una escalada de privilegios en el sistema."}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.3,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:dell:rugged_control_center:*:*:*:*:*:*:*:*","versionEndExcluding":"4.7","matchCriteriaId":"01646831-B95F-4537-A0D0-0BE43594030B"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000217705/dsa-2023-340","source":"security_alert@emc.com","tags":["Vendor Advisory"]},{"url":"https://www.dell.com/support/kbdoc/en-us/000217705/dsa-2023-340","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}