{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-15T03:53:09.469","vulnerabilities":[{"cve":{"id":"CVE-2023-39181","sourceIdentifier":"productcert@siemens.com","published":"2023-08-08T10:15:17.080","lastModified":"2024-11-21T08:14:51.683","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Solid Edge SE2023 (All versions < V223.0 Update 7). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Solid Edge SE2023 para todas las versiones anteriores a la V223.0 Update 7. La aplicación afectada contiene una escritura fuera de los límites más allá del final de un búfer asignado mientras analiza un archivo PAR especialmente diseñado. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*","versionEndExcluding":"se2023","matchCriteriaId":"F20768FD-EB6F-40EA-BDEA-17C9BA60A1E6"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2023:-:*:*:*:*:*:*","matchCriteriaId":"A8332862-1FB4-4824-9665-5A50184EB366"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack1:*:*:*:*:*:*","matchCriteriaId":"31441523-2923-4028-83E9-AAB998120A0E"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack2:*:*:*:*:*:*","matchCriteriaId":"7986AB87-876E-4E47-AEEB-9936491AA535"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack3:*:*:*:*:*:*","matchCriteriaId":"734D353F-4DBF-4001-8BC2-0760BE40BE55"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack4:*:*:*:*:*:*","matchCriteriaId":"63FCD2EA-EFCF-4959-B5C2-801E870B37AE"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack5:*:*:*:*:*:*","matchCriteriaId":"22949AFB-EF6F-4DF9-953B-5372686574B9"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:solid_edge:se2023:maintenance_pack6:*:*:*:*:*:*","matchCriteriaId":"8437DCAC-5CEC-4C52-80DE-91F785CB3F8E"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-811403.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-811403.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}