{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T16:39:04.629","vulnerabilities":[{"cve":{"id":"CVE-2023-38680","sourceIdentifier":"productcert@siemens.com","published":"2023-08-08T10:15:16.677","lastModified":"2024-11-21T08:14:02.270","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21132)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Tecnomatix Plant Simulation V2201 (Todas las versiones inferiores a V2201.0008), Tecnomatix Plant Simulation V2302 (Todas las versiones inferiores a V2302.0002). La aplicación afectada contiene una escritura fuera de límites más allá del final de un búfer asignado mientras analiza un archivo SPP especialmente diseñado. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual. (ZDI-CAN-21132)"}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*","versionStartIncluding":"2201","versionEndExcluding":"2201.0008","matchCriteriaId":"0E8C9093-BD78-4ECE-9221-A889371B3839"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:tecnomatix:*:*:*:*:*:*:*:*","versionStartIncluding":"2302","versionEndExcluding":"2302.0002","matchCriteriaId":"C7103507-EE73-42FF-9DAB-37DD06467591"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-764801.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}