{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-30T20:24:47.789","vulnerabilities":[{"cve":{"id":"CVE-2023-37500","sourceIdentifier":"psirt@hcl.com","published":"2023-08-03T22:15:12.517","lastModified":"2026-06-17T06:08:20.797","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A Persistent Cross-site Scripting (XSS) vulnerability can be carried out on certain pages of Unica Platform.  An attacker could hijack a user's session and perform other attacks.\n"}],"affected":[{"source":"psirt@hcl.com","affectedData":[{"vendor":"HCL Software","product":"HCL Unica Platform","defaultStatus":"unaffected","versions":[{"version":"<12.1.1","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"psirt@hcl.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2024-09-27T21:49:50.882280Z","id":"CVE-2023-37500","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hcltech:unica:*:*:*:*:*:*:*:*","versionEndExcluding":"12.1.1","matchCriteriaId":"633B4227-22EA-48D7-9962-C0880AC6F218"}]}]}],"references":[{"url":"https://support.hcltechsw.com/csm?id=kb_article&sysparm_article=KB0106554","source":"psirt@hcl.com","tags":["Vendor Advisory"]},{"url":"https://support.hcltechsw.com/csm?id=kb_article&sysparm_article=KB0106554","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}