{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-11T23:06:50.344","vulnerabilities":[{"cve":{"id":"CVE-2023-36635","sourceIdentifier":"psirt@fortinet.com","published":"2023-09-07T13:15:08.433","lastModified":"2024-11-21T08:10:08.487","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An improper access control in Fortinet FortiSwitchManager version 7.2.0 through 7.2.2\r\n7.0.0 through 7.0.1 may allow a remote authenticated read-only user to modify the interface settings via the API."},{"lang":"es","value":"Un control de acceso incorrecto en Fortinet FortiSwitchManager, versiones 7.2.0 a 7.2.2 y versiones 7.0.0 a 7.0.1, puede permitir que un usuario remoto autenticado con permisos de solo lectura modifique la configuración de la interfaz a través de la API."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":4.2},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiswitchmanager:7.0.0:*:*:*:*:*:*:*","matchCriteriaId":"5B4A6B0D-1614-443B-8EBA-A8FBC2E1A832"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiswitchmanager:7.0.1:*:*:*:*:*:*:*","matchCriteriaId":"331A1766-4EBA-4519-A8ED-E0DD68A187E9"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiswitchmanager:7.2.0:*:*:*:*:*:*:*","matchCriteriaId":"2B73D78B-2270-45B7-854E-F985B8D88F3B"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiswitchmanager:7.2.1:*:*:*:*:*:*:*","matchCriteriaId":"469E9E1C-154C-41CB-AC83-FBE5E6FA83EB"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiswitchmanager:7.2.2:*:*:*:*:*:*:*","matchCriteriaId":"959248C7-DC92-4968-87F9-2A2CDF84F7BE"}]}]}],"references":[{"url":"https://fortiguard.com/psirt/FG-IR-22-174","source":"psirt@fortinet.com","tags":["Not Applicable","Vendor Advisory"]},{"url":"https://fortiguard.com/psirt/FG-IR-22-174","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Not Applicable","Vendor Advisory"]}]}}]}