{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-10T01:08:08.486","vulnerabilities":[{"cve":{"id":"CVE-2023-35796","sourceIdentifier":"productcert@siemens.com","published":"2023-10-10T11:15:11.733","lastModified":"2024-11-21T08:08:43.457","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)"},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEMA Server V14 (todas las versiones). La aplicación afectada sanitiza incorrectamente ciertos datos de configuración SNMP recuperados de los dispositivos monitorizados. Un atacante con acceso a un dispositivo monitorizado podría realizar un ataque de Cross-Site Scripting (XSS) almacenado que puede llevar a la ejecución de código arbitrario con privilegios \"SYSTEM\" en el servidor de aplicaciones. (ZDI-CAN-19823)"}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","baseScore":8.3,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.6,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","baseScore":9.0,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.3,"impactScore":6.0}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinema_server:14.0:*:*:*:*:*:*:*","matchCriteriaId":"85D4624C-8FF6-43E7-9098-5BD106EF6972"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-594373.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}