{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T19:05:01.649821800Z","vulnerabilities":[{"cve":{"id":"CVE-2023-34999","sourceIdentifier":"psirt@bosch.com","published":"2023-09-18T11:15:41.867","lastModified":"2024-11-21T08:07:48.203","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A command injection vulnerability exists in RTS VLink Virtual Matrix Software Versions v5 (< 5.7.6) and v6 (< 6.5.0) that allows an attacker to perform arbitrary code execution via the admin web interface."},{"lang":"es","value":" Existe una vulnerabilidad de inyección de comandos en RTS VLink Virtual Matrix Software versiones v5 (&lt; 5.7.6) y v6 (&lt; 6.5.0) que permite a un atacante realizar la ejecución de código arbitrario a través de la interfaz web de administración."}],"metrics":{"cvssMetricV31":[{"source":"psirt@bosch.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.7,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}]},"weaknesses":[{"source":"psirt@bosch.com","type":"Secondary","description":[{"lang":"en","value":"CWE-94"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-77"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:bosch:rts_vlink_virtual_matrix:*:*:*:*:*:*:*:*","versionStartIncluding":"5.0.0","versionEndExcluding":"5.7.6","matchCriteriaId":"CB340A4E-132C-46A5-8A80-B1A4C45A2CE8"},{"vulnerable":true,"criteria":"cpe:2.3:a:bosch:rts_vlink_virtual_matrix:*:*:*:*:*:*:*:*","versionStartIncluding":"6.0.0","versionEndExcluding":"6.5.0","matchCriteriaId":"E6A940F1-AF61-43F8-BABA-2E14EAD2E0D4"}]}]}],"references":[{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-893251-BT.html","source":"psirt@bosch.com","tags":["Patch","Vendor Advisory"]},{"url":"https://psirt.bosch.com/security-advisories/BOSCH-SA-893251-BT.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}