{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-30T01:25:11.529","vulnerabilities":[{"cve":{"id":"CVE-2023-34392","sourceIdentifier":"security@selinc.com","published":"2023-08-31T16:15:10.123","lastModified":"2024-11-21T08:07:09.853","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nA Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\n\n\nThis issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.\n\n"},{"lang":"es","value":"Una vulnerabilidad de ausencia de autenticación para función crítica en el Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator podría permitir a un atacante ejecutar comandos arbitrarios en dispositivos gestionados por un operador de dispositivo autorizado.\n\nConsulte el Manual de Instrucciones Apéndice A y Apéndice E con fecha 20230615 para más detalles.\n\nEste problema afecta a SEL-5037 SEL Grid Configurator: antes de 4.5.0.20."}],"metrics":{"cvssMetricV31":[{"source":"security@selinc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H","baseScore":8.2,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.5,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"security@selinc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:selinc:sel-5037_sel_grid_configurator:*:*:*:*:*:*:*:*","versionEndExcluding":"4.5.0.20","matchCriteriaId":"8DE1284E-619F-49AC-AE96-0A4ECD76292B"}]}]}],"references":[{"url":"https://selinc.com/support/security-notifications/external-reports/","source":"security@selinc.com","tags":["Vendor Advisory"]},{"url":"https://www.nozominetworks.com/blog/","source":"security@selinc.com","tags":["Third Party Advisory"]},{"url":"https://selinc.com/support/security-notifications/external-reports/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.nozominetworks.com/blog/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}