{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-15T00:25:34.209","vulnerabilities":[{"cve":{"id":"CVE-2023-32674","sourceIdentifier":"hp-security-alert@hp.com","published":"2023-06-12T22:15:10.077","lastModified":"2026-06-17T05:59:21.710","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Certain versions of HP PC Hardware Diagnostics Windows are potentially vulnerable to buffer overflow."}],"affected":[{"source":"hp-security-alert@hp.com","affectedData":[{"vendor":"HP Inc.","product":"HP PC Hardware Diagnostics Windows","versions":[{"version":"See HP Security Bulletin reference for affected versions.","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-01-03T18:09:52.419501Z","id":"CVE-2023-32674","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-120"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-120"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hp:pc_hardware_diagnostics:*:*:*:*:*:windows:*:*","versionEndExcluding":"2.2.0.0","matchCriteriaId":"1517606E-FD3B-4A75-A986-60F093203F2C"}]}]}],"references":[{"url":"https://support.hp.com/us-en/document/ish_8128401-8128440-16/hspbhf03848","source":"hp-security-alert@hp.com","tags":["Vendor Advisory"]},{"url":"https://support.hp.com/us-en/document/ish_8128401-8128440-16/hspbhf03848","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}