{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T09:32:11.420","vulnerabilities":[{"cve":{"id":"CVE-2023-32276","sourceIdentifier":"vultures@jpcert.or.jp","published":"2023-06-19T05:15:09.480","lastModified":"2024-12-23T22:15:07.457","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Stack-based buffer overflow vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted V8 file may lead to information disclosure and/or arbitrary code execution."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fujielectric:tellus:4.0.15.0:*:*:*:*:*:*:*","matchCriteriaId":"30687838-02B8-43D9-AE6F-BD508BC2B3AF"},{"vulnerable":true,"criteria":"cpe:2.3:a:fujielectric:tellus_lite:4.0.15.0:*:*:*:*:*:*:*","matchCriteriaId":"3375800A-B58B-4D4E-A68A-BE8D9CACDBAB"}]}]}],"references":[{"url":"https://jvn.jp/en/vu/JVNVU98818508/","source":"vultures@jpcert.or.jp","tags":["Third Party Advisory"]},{"url":"https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php","source":"vultures@jpcert.or.jp","tags":["Release Notes"]},{"url":"https://jvn.jp/en/vu/JVNVU98818508/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]},{"url":"https://monitouch.fujielectric.com/site/download-e/03tellus_inf/index.php","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Release Notes"]}]}}]}