{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-06T13:29:16.235","vulnerabilities":[{"cve":{"id":"CVE-2023-32134","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2024-05-03T02:15:16.510","lastModified":"2025-01-03T20:32:33.060","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Sante DICOM Viewer Pro DCM File Parsing Use-After-Free Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Sante DICOM Viewer Pro. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.\n\nThe specific flaw exists within the parsing of DCM images. The issue results from the lack of validating the existence of an object prior to performing operations on the object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-15629."},{"lang":"es","value":"Sante DICOM Viewer Pro DCM Vulnerabilidad de ejecución remota de código de Use-After-Free. Esta vulnerabilidad permite a atacantes remotos ejecutar código arbitrario en instalaciones afectadas de Sante DICOM Viewer Pro. Se requiere la interacción del usuario para aprovechar esta vulnerabilidad, ya que el objetivo debe visitar una página maliciosa o abrir un archivo malicioso. La falla específica existe en el análisis de imágenes DCM. El problema surge de la falta de validación de la existencia de un objeto antes de realizar operaciones sobre él. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del proceso actual. Era ZDI-CAN-15629."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-416"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-416"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:santesoft:dicom_editor:*:*:*:*:*:*:*:*","versionEndExcluding":"7.8.12","matchCriteriaId":"95F33AB2-1322-498F-ADD5-F4089EBD6A02"},{"vulnerable":true,"criteria":"cpe:2.3:a:santesoft:dicom_viewer_pro:*:*:*:*:*:*:*:*","versionEndExcluding":"11.8.12","matchCriteriaId":"4DF55FB8-25BE-40C9-85BD-5461C539818A"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-526/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-23-526/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}