{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T23:22:21.641","vulnerabilities":[{"cve":{"id":"CVE-2023-3127","sourceIdentifier":"productsecurity@jci.com","published":"2023-07-11T22:15:09.907","lastModified":"2024-11-21T08:16:31.063","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An unauthenticated user could log into iSTAR Ultra, iSTAR Ultra LT, iSTAR Ultra G2, and iSTAR Edge G2 with administrator rights."}],"metrics":{"cvssMetricV31":[{"source":"productsecurity@jci.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:L","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"LOW"},"exploitabilityScore":1.6,"impactScore":5.3},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"productsecurity@jci.com","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:istar_ultra_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"6.8.6","versionEndExcluding":"6.9.2","matchCriteriaId":"C49B542F-166F-4385-B910-705064C5B109"},{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:istar_ultra_firmware:6.9.2:-:*:*:*:*:*:*","matchCriteriaId":"7AF26AC6-083F-4BB3-86AF-8730E2BFD397"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:johnsoncontrols:istar_ultra:-:*:*:*:*:*:*:*","matchCriteriaId":"F89B3465-8274-49E5-8290-1893B4C2AC07"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:istar_ultra_lt_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"6.8.6","versionEndExcluding":"6.9.2","matchCriteriaId":"C9D2D8D5-A67D-45DD-A718-37C29D633931"},{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:istar_ultra_lt_firmware:6.9.2:-:*:*:*:*:*:*","matchCriteriaId":"5294AD55-D524-4E5A-ACEC-7685974A9415"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:johnsoncontrols:istar_ultra_lt:-:*:*:*:*:*:*:*","matchCriteriaId":"A759A7FA-5AEA-48D8-B40E-B0DA7223F0F4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:istar_ultra_g2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.9.2","matchCriteriaId":"85B7CE5A-A2A1-4433-B85A-8B6255B3D657"},{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:istar_ultra_g2_firmware:6.9.2:-:*:*:*:*:*:*","matchCriteriaId":"7A3A4BDF-12FE-43C9-8CD4-0CA764E08175"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:johnsoncontrols:istar_ultra_g2:-:*:*:*:*:*:*:*","matchCriteriaId":"A148D700-5542-473A-B88F-849180658787"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:edge_g2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.9.2","matchCriteriaId":"6D26CC65-9CCF-41A5-BC1B-2AAFAF9393E1"},{"vulnerable":true,"criteria":"cpe:2.3:o:johnsoncontrols:edge_g2_firmware:6.9.2:-:*:*:*:*:*:*","matchCriteriaId":"C629C7CF-4372-494D-8B1C-CC4795356E03"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:johnsoncontrols:edge_g2:-:*:*:*:*:*:*:*","matchCriteriaId":"95BBCCE7-3098-41B0-A388-53E3DA9A29B9"}]}]}],"references":[{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-192-02","source":"productsecurity@jci.com","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories","source":"productsecurity@jci.com","tags":["Vendor Advisory"]},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-192-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}