{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-04T10:15:24.110","vulnerabilities":[{"cve":{"id":"CVE-2023-31169","sourceIdentifier":"security@selinc.com","published":"2023-08-31T16:15:09.230","lastModified":"2024-11-21T08:01:32.963","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"\nAn Improper Handling of Unicode Encoding vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator.\n\n\n\n\n\nSee Instruction Manual Appendix A and Appendix E dated 20230615 for more details.\nThis issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0.\n\n"},{"lang":"es","value":"Una vulnerabilidad de manejo inadecuado de la codificación Unicode en el software Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet podría permitir a un atacante incrustar instrucciones que podrían ser ejecutadas por un operador de dispositivo autorizado.\n\nConsulte el Apéndice A y el Apéndice E del Manual de Instrucciones con fecha 20230615 para más detalles.\nEste problema afecta al software SEL-5030 acSELerator QuickSet: hasta la versión 7.1.3.0."}],"metrics":{"cvssMetricV31":[{"source":"security@selinc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N","baseScore":4.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":1.2,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N","baseScore":5.7,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.1,"impactScore":3.6}]},"weaknesses":[{"source":"security@selinc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-176"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-755"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:selinc:sel-5030_acselerator_quickset:*:*:*:*:*:*:*:*","versionEndIncluding":"7.1.3.0","matchCriteriaId":"B7FE991E-8E2F-4B6D-A0F7-E9D67913B5B6"}]}]}],"references":[{"url":"https://selinc.com/support/security-notifications/external-reports/","source":"security@selinc.com","tags":["Vendor Advisory"]},{"url":"https://www.nozominetworks.com/blog/","source":"security@selinc.com","tags":["Third Party Advisory"]},{"url":"https://selinc.com/support/security-notifications/external-reports/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.nozominetworks.com/blog/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}