{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T17:11:01.020304100Z","vulnerabilities":[{"cve":{"id":"CVE-2023-30796","sourceIdentifier":"productcert@siemens.com","published":"2023-08-08T10:15:15.153","lastModified":"2024-11-21T08:00:55.130","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en JT Open (Todas las versiones inferiores a V11.4), JT Utilities (Todas las versiones inferiores a V13.4). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada al analizar archivos JT especialmente diseñados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-125"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-125"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt_open_toolkit:*:*:*:*:*:*:*:*","versionEndExcluding":"11.4","matchCriteriaId":"125D935D-0DE5-4732-983B-8DC221479FB3"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:jt_utilities:*:*:*:*:*:*:*:*","versionEndExcluding":"13.4","matchCriteriaId":"C1B0B2A2-1A1A-4B0F-B957-2D5B6EBDB0FE"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}